Назад Далее
Дата продажи
26.04.24
Выигрышное предложение
US 5 300 $
№ предложений
3
№ наблюдателей
13
ПРОДАНО!
СВЕДЕНИЯ О ЛОТЕ
Показания счетчика
3 017 Часы
Serial #
3 Stage Mast, 177 in Max Lift Height, 45 in Forks, 6 Cylinder Diesel Engine

Отчет о проверке



Please note that you are bidding on an item offered without IronClad Assurance®. Only basic item condition details are provided for your review and consideration in a purchase decision.
 
Model Description
Описание Подробности

This item is offered as-is, where-is with no IronClad Assurance, and a buyer may not dispute the condition of the item. IronPlanet claims no responsibility for the condition or description of this item. This item does not include any protection offered by IronClad Assurance. A buyer may NOT submit a dispute claim on this item.


Общий вид
Описание Рейтинг Подробности  
CE Mark No CE mark found
Hour Meter /Odometer Usage Reading** 3017 hrs - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Нажмите здесь, чтобы открыть фото и видео, прилагаемые к данному лоту.  
(8)


Control Station
Описание Рейтинг Подробности  
Ограниченная проверка работоспособности (cs) Unable to start engine with key switch. It was necessary to jump the starter solenoid to engage the starter to crank engine. Нажмите здесь, чтобы открыть фото и видео, прилагаемые к данному лоту.  
(6)


Engine
Описание Рейтинг Подробности  
Limited Function Check Needed a jump and either to start. Key switch will not activate starter solenoid. I manually energized the solenoid with a wire to crank and start the engine. The engine died a couple of times during inspection and got progressively more difficult to restart. The final time engine died at end of inspection engine would crank and would not start and run. POC was advised. Нажмите здесь, чтобы открыть фото и видео, прилагаемые к данному лоту.  
(9)


Drivetrain
Описание Рейтинг Подробности  
Limited Function Check The drivetrain was operational without a load.
(2)


Hydraulics
Описание Рейтинг Подробности  
Ограниченная проверка работоспособности The hydraulic system was operational.
(7)


Chassis Photos
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Описание Рейтинг Подробности  
(20)


Deficiencies
Описание Рейтинг Подробности  
Deficiencies Deficient Components/Systems Include but are not limited to: Ignition key switch would not energize starter solenoid, Control Station Section
 
NON-DISPUTABLE